CIX100 Maximum Capacity Configuration

Top  Previous  Next

Most Visited: Toshiba's All New IP5000 Series Phones | CIX40i: Big Features for Small Businesses and Branch Offices | Toshiba eManager FAQ | Toshiba CIX Business Phone Systems Product Line

Examples

Table 15        CIX100 Base Cabinet with Digital Telephones and Loop Start Line With or Without Caller ID

4 Universal Slots
40 Stations (Max.)
24 CO lines (Max.)
44 Stations + Analog loop start lines combined (Max.)

Stations

Analog loop start lines

40

4 (none can have Caller ID)

32

8 (all can have Caller ID)

32

16 (none can have Caller ID)

16

16 (8 can have Caller ID)

241

8 (none can have Caller ID)

 

1. Using ADKU.

Table 16        CIX100 Base and Expansion Cabinet with Analog Loop Start Lines

8 Universal Slots
72 Stations (Max.)
56 CO lines (Max.)
92 Stations + Analog Loop Start Lines combined (Max.)

Stations

Analog loop start lines

72

20 (none can have Caller ID)

72

16 (8 can have Caller ID)

64

32 (none can have Caller ID)

64

24 (8 can have Caller ID)

64

16 (all can have Caller ID)

48

40 (none can have Caller ID)

48

32 (8 can have Caller ID)

48

24 (16 can have Caller ID)

32

48 (none can have Caller ID)

32

40 (8 can have Caller ID)

32

32(16 can have Caller ID)

32

24 (24 can have Caller ID)

16

32 (24 can have Caller ID)

 

Table 17        CIX100 Base Only: Digital Telephones and T1 and/or PRI lines

4 Universal Slots
40 Stations (Max.)
48 lines (Max.)
64 Stations + T1 and/or PRI lines combined (Max.)

Stations

T1 and/or PRI lines

40

24/23

32

40/40

16

48/46

 

Table 18        CIX100 Base and Expansion Digital Telephones and with T1 and/or PRI lines

8 Universal Slots
72 Stations (Max.)
64 lines (Max.)
112 Stations + T1 and/or PRI lines
combined (Max.)

Stations

T1 and/or PRI lines1

72

40/40

64

48/48

56

56/48

48

64/48

 

1. PRI lines are limited to 48B channels.

Table 19        CIX100 Base Cabinet Only with Analog Tie, DID and /or Ground Start Lines

4 Universal Slots
40 Stations (Max.)
16 CO lines (Max.)
40 Stations + Analog Tie, DID, Ground Start Lines
combined (Max.)

Stations

Analog Tie, DID, and/or Ground Start Lines

40

4 line (Ground Start only)

32

8 lines (4 Tie/DID max.).

24

8 line any type

16

12 line any type

0

16 line any type

 

Table 20        CIX100 Base and Expansion Cabinet with Analog Tie, DID and/or Ground Start Lines

8 Universal Slots
72 Stations (Max.)
32 CO lines (Max.)
80 Stations + Analog Tie, DID and/or Ground Start Lines
combined (Max.)

Stations

Analog Tie, DID, and/or Ground Start Lines

72

12 lines (4 Tie/DID max.)

64

16 lines (8 Tie/DID max.)

56

16 lines (12 Tie/DID max.)

48

16 lines any type

48

20 lines (16 Tie/DID max.)

32

24 lines any type

16

28 lines any type

 

Universal Printed Circuit Cards installed in the Strata CIX670, CIX200 or CIX100 cabinets provide interfaces for stations, lines, and peripherals. Each circuit card measures 7.5 x 5.5 inches (190 x 140 mm) and mounts in the slot with a 44-pin backplane connector. Circuit Card external

connections to station equipment are made to the Main Distribution Frame (MDF) using industry- standard connectors.

Important! This chapter does not apply to the Strata CIX40, except for GVPH, MIPU16 and MIPU24.

 


























KTS CUSTOMER USER GROUP RESOURCES | TOSHIBA CIX PHONE SYSTEMS
Sponsors Web Site
| http://www.ip-office-telephone-systems.com
Telephone Number
| (888) 4-TOSHIBA
Telephone Equipment Service Area By California County:
Los Angeles, Orange, Riverside, San Bernardino, San Diego
Site Managed By
| ABCI Web Marketing